TM-10-5411-235-13
OPERATOR TROUBLESHOOTING PROCEDURES
0009 00
Table 2. Operator Troubleshooting Procedures
INITIAL SETUP:
Maintenance Level
Materials/Parts
Operator
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Inspect the mounting hardware
1. Excessive Noise and
1. Secure/Replace missing
securing the LMS I to HMMWV
Vibration
hardware
1.
Inspect exterior & interior walls for
2. Excessive Air/Moisture
1. Notify Unit Maintenance
damage
in Shelter
2. Inspect to ensure drain plug is
2. Re-install drain plug.
installed
See 0037 00-1
1. Inspection of door jamb for
1. Clean door jamb of
3. Personnel Door
evidence of obstruction or dirt
obstruction
Binding
2. Inspect for broken door hinge/or
2. Replace door hinge. Notify
loose or missing hardware
Supervisor/Unit
Maintenance
1. Inspect Roller Latch Assembly for
4. Personnel Door Fails
missing hardware or bent control
1. Notify Unit Maintenance if
to Lock
rods
damaged Roller Latch
Assembly
2. Roller Latch Assembly fails to
completely secure door
2. Notify Unit Maintenance of
door shimming requirement
1. Inspect EMI and weather gasket
5. Personnel Door Fails
for damage
1. Notify Unit Maintenance of
to Close Tightly
damaged seals
1. Inspect for proper meeting of
6. Damage to Shelter
shelter walls and floor and/or
1. Notify Unit Maintenance
Floor
missing hardware
END OF WORK PACKAGE