TM 10-5411-224-14
Table 4-1. Unit Preventive Maintenance Checks and Services for LMS.
Location
Item
No.
Interval
Item to
Check/
Service
Procedure
Not
Fully
Mission
Capable if:
1
Monthly
Lifting rings
Inspect for excessive wear.
Excessively worn.
2
Semi-
annually
Walls,
floors
and
ceiling panels
Inspect
for
punctures
and
delamination.
Punctures are
present.
3
Semi-
annually
EMI/RFI gasket
Make sure EMI/RFI gasket is in
good condition.
Gasket is damaged.
4
Semi-
annually
Weather gasket
Make sure gasket is in good
condition.
Gasket is damaged.
5
Semi-
annually
Lifting ring
bumpers
Inspect for major damage or
loss.
6
Semi-
annually
Shelter pads
Inspect for major damage.
7
Semi-
annually
Shelter steps
Inspect for corrosion and loose
or missing hardware.
Steps excessively
corroded or hardware
loose or missing.
8
Semi-
annually
Roof handle
Ensure
handle
is
securely
mounted and operates smoothly.
Handle damaged or
missing
4-11