TM 10-5411-224-14
Table 2-1. Operator Preventive Maintenance Checks and Services for LMS.
Location
Item No.
Interval
Item to
Check/
Service
Procedure
Not Fully Mission
Capable if:
1
Before
Door Handles
Make sure door handles operate
smoothly without binding or
jamming.
Door cannot be
opened or closed
securely.
2
Before
Door
Stay
Arm
Assembly
Make
sure
door
stay
arm
engages keeper securely and
easily.
3
Before
Door Assembly
Make sure door opens and
closes
smoothly
without
binding. Check hinges for
corrosion or loose or missing
hardware.
Lubricate
as
necessary.
.
Make sure drip molding is intact
Check
door
surfaces
for
punctures.
Punctures are
present.
.
Make sure weather gasket is in
good condition.
Gasket is
damaged.
.
Make sure EMI/RFI gasket is in
good condition
Gasket is
damaged.
4
Before
Wall,
Floor
and
Ceiling Panels
Inspect
for
punctures
and
delamination.
Punctures are
present.
5
Before
Drain Plug
Make sure drain plug is in
place.
Drain
plug
is
missing or does
not seal.
6
Before
Roof Access Steps
Make
sure
steps
operate
smoothly and stay in the up or
down position.
Steps damaged or
missing.
7
Before
Roof Handle
Check for corrosion and loose
or missing hardware.
Handle damaged
or missing.
8
After
Door Handles
Ensure
handles
operate
smoothly without binding or
jamming.
Door
cannot
be
opened or closed
securely.
2-3