TM 10-5411-203-13
4-21.
CONNECTOR ASSEMBLY PUNCTURE REPAIR INSTRUCTIONS (CONT)
2.
Clean area around hole (1).
3.
Using tongue depressor (2), dab adhesive onto hole (1) in connector assembly (3),
4.
Work adhesive into connector assembly (3) immediately and bridge hole (1) with adhesive to seal it.
5.
Let adhesive dry.
NOTE
FOLLOW-ON MAINTENANCE: If required, install Complexing Kit Passageway. (Refer to
para 2-4.)
4-27