4-21.
CONNECTOR ASSEMBLY PUNCTURE REPAIR INSTRUCTIONS
This task covers:
Repair
INITIAL SETUP
Tools
Repair kit, tentage (Appendix B, Section III, Item 2)
Tape, measuring (Appendix B, Section III, Item 7)
Parts/Materials
Cloth, coated (Appendix D, Item 12)
Tongue Depressor (Appendix D, Item 5)
Equipment Condition
Complexing Kit Passageway removed from shelter. (Refer to para 2-5.)
REPAIR
WARNING
The adhesive has a high alcohol content and is highly flammable Use only in a well
ventilated area away from open flame. Do not smoke. Failure to follow these safety
precautions could result in dizziness, fainting, severe burns or death,
NOTE
Adhesive dries quickly. Do not leave lid off adhesive can for more than five minutes.
Replace lid on adhesive can immediately after use.
1.
Measure hole in connector assembly to see if 1/8 in. (3.2 mm) across or less in all directions. To repair holes
larger than 1/8 in. (3.2 mm) across refer to paragraph 4-22.
4-26