TM 10-5411-203-134-21.CONNECTOR ASSEMBLY PUNCTURE REPAIR INSTRUCTIONSThis task covers:RepairINITIAL SETUPToolsRepair kit, tentage (Appendix B, Section III, Item 2)Tape, measuring (Appendix B, Section III, Item 7)Parts/MaterialsCloth, coated (Appendix D, Item 12)Tongue Depressor (Appendix D, Item 5)EquipmentConditionComplexing Kit Passageway removed from shelter. (Refer to para 2-5.)REPAIRWARNINGThe adhesive has a high alcohol content and is highly flammable Use only in a wellventilated area away from open flame. Do not smoke. Failure to follow these safetyprecautions could result in dizziness, fainting, severe burns or death,NOTEAdhesive dries quickly. Do not leave lid off adhesive can for more than five minutes.Replace lid on adhesive can immediately after use.1.Measure hole in connector assembly to see if 1/8 in. (3.2 mm) across or less in all directions. To repair holeslarger than 1/8 in. (3.2 mm) across refer to paragraph 4-22.4-26