TM 10-5411-201-14
T.O. 35E4-178-1
3-2.
(cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
NO POWER AT HEATER/AC SUPPLY.
Step 1.
Check that outside power is properly connected to service
entrance connector on power entry panel, and check general
condition of cable and connectors.
a.
Make proper power connection.
b.
Check for defective cable or connectors.
Step 2.
Check and reset circuit breakers.
Notify organizational maintenance.
Section II.
OPERATOR MAINTENANCE PROCEDURES
3-3 GENERAL.
Authorized maintenance procedures to be performed by operator
include replacement of area light assembly, replacement of light bulbs, hinged
roof area ceiling lights, hinged panel leveling jack assemblies, endwall
closeout panel, sidewall closeout panels, ECU intake panel, ECU return panel,
container lift jack assemblies, storm configuration components, support
braces, and leveling jack extensions.
3-4.
AREA LIGHT ASSEMBLY REPLACEMENT
This task covers:
a.
Removal
b.
Installation
WARNING
Disconnect power of circuit involved by setting
circuit breaker to off position.
3-4