TM 10-5411-201-14
T.O. 35E4-178-1
2-12.
(cont)
C A U T I O N
Do not continue to jack since this may cause
structural damage to hinged endwall.
z.
Use support struts to lower hinged
roof to rest on hinged endwalls and sidewall.
aa. Remove lock pins from support struts.
Compress support struts and secure in support
brackets on hinged roof with lock pins.
ab. Adjust leveling jack to make sure
positioning marks on hinged roof and hinged
sidewall are properly aligned.
ac. Obtain four removable latches from
equipment container and install two on hinged
sidewall. and two on hinged endwalls.
ad. Engage all. panel latches to compress
seals. Engage nonremovable latches first then
removable latches.
ae . Visually check to make sure all
seals are properly compressed.
af. Remove support braces.
ag. Stow support braces in equipment
container.
2-13. CEILING LIGHTS AND UTILITY OUTLETS INSTALLATION
a.
Ceiling light installation.
W A R N I N G
In the event of lamp breakage, care must be taken
in removal of broken glass fragments and white
phosphorous dust that may be dispersed within fixture.
Inhalation of phosphorous dust could cause dangerous injury.
2-25