TM 10-5411-201-14T.O. 35E4-178-14-41.(cent)W A R N I N GMethylethylketone is flammable and toxic and shall beused only in a well-ventilated area away from all sparksor open flame.c.Sand using sandpaper (Item 17, Appendix E) only if required toremove material not taken off in preceding step.d.Wipe bonding surface with a clean cloth (Item 5, Appendix E)dampened with solvent (Item 20, Appendix E) and immediately wipe solvent fromsurface with a clean, dry cloth.CAUTIONSeals shall not be washed with any aromatic hydrocarbon(such as benzene, toluene, or xylene) which will causedeterioration.e.Clean seal with a lint-free cloth by dry wiping prior to bonding.f.Brush sealant (Item 18, Appendix E) on mating surfaces of seal andbonding surface.g.When sealant is tacky (approximately 5 minutes), place seal inposition, press firmly to seat and ensure contact with mating surface.h.If seal is the type that has a retaining strip, seal shall be bondedprior to riveting retaining strip,(Refer to paragraph 4-33 for blind rivetinstallation.)i .After installing rivets, using hand blind riveter, cover rivets andseal with sealing compound (Item 19, Appendix E).4-179