TM 10-5411-201-14
T.O. 35E4-178-1
4-40.
(cont)
W A R N I N G
Methylethylketone is flammable and toxic and shall be
used only in a well-ventilated area away from sparks or
open flame.
Gloves should be worn during use.
d.
Wipe patches with a clean cloth (Item 5, Appendix E) dampened with
solvent and immediately wipe solvent (Item 20,
Appendix E) from surfaces with
a clean, dry cloth.
e.
Apply a thick coat of adhesive to one side of each patch.
f.
Place core plug between two patches to create a sandwich panel.
g.
Apply pressure and heat using tripod base heat lamp, Appendix B,
Item 16, at 200° F (93.9° C) for 40 to 60 minutes to fully cure adhesive.
h.
Cut bonded sandwich panel to same size as cutout opening (step
Ensure core ribbon direction is same as panel.
i.
Cut two aluminum patches 1 1/2 inch (3.8 cm) larger all around
cutout opening.
a) .
than
4-176