TM 10-5411-201-14T.O. 35E4-178-14-40.(cont)W A R N I N GMethylethylketone is flammable and toxic and shall beused only in a well-ventilated area away from sparks oropen flame.Gloves should be worn during use.d.Wipe patches with a clean cloth (Item 5, Appendix E) dampened withsolvent and immediately wipe solvent (Item 20,Appendix E) from surfaces witha clean, dry cloth.e.Apply a thick coat of adhesive to one side of each patch.f.Place core plug between two patches to create a sandwich panel.g.Apply pressure and heat using tripod base heat lamp, Appendix B,Item 16, at 200° F (93.9° C) for 40 to 60 minutes to fully cure adhesive.h.Cut bonded sandwich panel to same size as cutout opening (stepEnsure core ribbon direction is same as panel.i.Cut two aluminum patches 1 1/2 inch (3.8 cm) larger all aroundcutout opening.a) .than4-176