TM 10-5411-201-14
T.O. 35E4-178-1
4-38.
(cont)
g. Center patch over damaged area and drill No. 30 diameter holes in
panel skin.
Use holes in patch as a template.
h.
Index patch and panel skin with a mark to allow patch to be replaced
in same orientation.
i.
Deburr all drill holes.
WARNING
Methylethylketone is flammable and toxic and shall
be used only in a well-ventilated area away from all
sparks or open flame.
j.
Wipe damaged area and patch with a clean cloth (Item 5, Appendix E)
dampened in solvent (Item 20, Appendix E) and immediately wipe solvent from
surfaces with a clean, dry cloth.
k.
Mix sufficient amount of adhesive (Item 1, Appendix E) in accordance
with manufacturers Instructions.
4-171