TM 10-5411-201-14T.O. 35E4-178-14-35.REPAIR OF DEPRESSION OR SMALL PUNCTURE.NOTEThe following procedure covers repair of a depressionor small puncture in any shelter panel skin (depressionexceeding 2 square in. (12.9 sq cm) or deeper than0.25 in. (6.4 mm) but not larger than 4 square in.(25.8 sq cm) or puncture not larger than 1 square in.(6.5 sq cm)).W A R N I N GWear safety goggles fora.Drill two 1/8 in. (3.18within damaged area.b.Dry panel per paragrapheye protection from flying metal chips.mm) diameter holes4-32, if required.c.Mix small quantity of adhesive (Item 1,Appendix E) in accordance with manufacturer’sinstructions.d.Transfer adhesive to caulking gun and injectadhesive through two drilled holes to fill core cellscompletely.e.Apply heat using tripod base heat lamp,Appendix B, Item 16, at 200°F (93.3°C) for 40 to60 minutes to fully cure adhesive.Alternate cures:150° F for 4 hours or 75° F for 72 hours.f.Check by tapping damaged area to ensure complete filling of cells.g.Sand damaged area with sandpaper (Item 17, Appendix E) to remove alltraces of paint and excess adhesive.W A R N I N GMethylethylketone is flammable and toxic and shallbe used only in a well-ventilated area away fromall sparks or open flame.Gloves should be wornduring use.4-165