TM 10-5411-201-14
T.O. 35E4-178-1
4-26.
(cont)
1.
2.
3.
4.
5.
6.
7.
8.
Remove cargo doors in accordance
with paragraphs 4-17 and 4-18.
Remove hinged endwalls adjacent
fixed cargo endwall in accordance
with paragraph 4-21.
Remove screws (l), lockwashers
(2), and washers (3) securing
hinged endwall hinge (4) to fixed
endwall and corner post.
Remove bolts (5), nuts (6) and
washers (7) securing fixed endwall
(13) to corner posts (8).
Remove bolts (9), lockwashers (10),
and washers (11) securing drip cap
(12) and fixed endwall (13) to
fixed roof.
Remove eight screws (14), eight
screws (15), shear plate (16)
and shims (17 and 18).
Remove bolts (9), lockwashers (10),
and washers (11) securing fixed
endwall (13) to fixed floor.
Support fixed endwall, cut through
adhesive sealant, and remove by
using a putty knife (or similar tool)
to break bond between endwall and
fixed roof, fixed floor, and corner
posts.
4-126