TM 10-5411-200-14
T.O. 35E4-177-1
4-22.
HINGED SIDEWALL REPLACEMENT AND REPAIR
This task covers:
a. Removal
b.
Disassembly
d.
Repair
c.
e. Assembly
Cleaning, Inspection
f.
Installation
INITIAL SETUP
Special TOOlS
Hand blind riveter, Appendix B,
Item 2
Snap ring pliers, Appendix B,
Item 10
Installation tool, Appendix B,
Item 3
Installation tool, Appendix B,
Item 14
Electric drill; portable,
Appendix B, Item 6
Standard TOOlS
General mechanics tool kit
Personnel - 4
1 Electrician
Equipment Condition
Equipment Condition
Closeout and ECU panels removed
from hinged sidewalls
Materials
Adhesive, Item 1, Appendix E
Adhesive, Item 2, Appendix E
Adhesive, Item 3, Appendix E
Sealant, Item 18, Appendix E
Sealing Compound, Item 19,
Appendix E
Spray Lubricant, Item 25,
Appendix E
NOTE
The following procedures apply to left and
right hinged sidewalls.
REMOVAL
Hinged Sidewall
WARNING
The shelter contains voltages that are dangerous if
contacted.
Before removing or installing electrical
cables or components,
make certain electrical power
is completely disconnected from circuit involved.
Support cables must be locked out prior to removal
of hinged sidewall.
NOTE
Remove only those electrical components that will
interfere with removal of a particular panel.
1.
Install support braces.
2.
Set circuit breaker CB3 and CB7 or CB5 to OFF position.
4-97