TM 10-5411-200-14
T.O. 35E4-177-1
4-10. (cont)
8.
Pull wiring down into light fixture adapter (9), position upper conduit (24) in hole at top of adapter, and
tighten offset connector (16).
9.
Tighten screw (17) at rear of offset connector (18).
10.
Pass wiring for switch (4) through lower hole of light fixture adapter (9) and thread through lower conduit
(14).
11.
Position lower conduit (14) in hole at bottom of light fixture adapter (9) and tighten upper insulating
connector (15).
12.
Pull wiring through conduit (14) and:
a. For units prior to S/N 1089, pull wiring through elbow connector (26) and into outlet box (27).
b. For units with S/N 1069 and subsequent, pull wiring into outlet box (27).
13.
Position lower conduit (14) into:
a. Elbow connector (26) (for units prior to S/N 1069) and tighten lower insulating connector (15).
b. Conduit outlet box (27) (for units with S/N 1069 and subsequent) and tighten lower insulating
connector (15).
14.
Position outlet box (27) against wall and secure with two screws (30) and lockwashers (31).
15.
Position switch (4) near outlet box (27) and connect wires. (Refer to paragraph 4-46.)
4-26
CHANGE 8