TM 10-5410-284-13&P
TM 10602A-13&P
LIGHTWEIGHT MAINTENANCE ENCLOSURE (LME)
0022 00
ASSEMBLY, 50 WATT MILITARY LIGHT
0022 00-1/2 blank
WARNING
THIS SECTION COVERS:
Inspect, Replace, Test, Repair
INITIAL SETUP
Lights, unpacked or in operation
Maintenance Level
Unit
Materials/Parts
Tools and Special Tools
Tool Kit, General Mechanics (WP 0028, Table 0027-2, Item 3)
GENERAL
This procedure contains information and instructions to keep the LME lights in good working order by
inspecting, testing, repairing or replacing individual lights.
If the lights are in use, limit inspection of the individual lights to a visual
inspection from the ground to avoid injuries from falls.
INSPECT
Inspect individual light covers for cracks or discoloration. Inspect power cords on individual lights for
frayed cords and broken or damaged plugs.
REPLACE
Replace a light that does not function properly after testing, or that has frayed power cord. Replace light
bulbs in individual lights as necessary. Replace frayed, ripped or missing support straps as necessary.
TEST
Test each light (if not in use) by plugging the power cord into a 120V AC grounded outlet. If the lights are
installed in the LME, test by operating the LIGHTS switch on the power distribution box (The box must be
connected to a power source for the lights to work). If none of the installed lights operate, check the
circuit breakers and reset if necessary.
REPAIR
Repair the lights by replacing individual components described under REPLACE, above.
END OF WORK PACKAGE