TM 10-5410-284-13&P
TM 10602A-13&P
LIGHTWEIGHT MAINTENANCE ENCLOSURE (LME)
0021 00
FOOT LOOP
0021 00-1/2 blank
THIS SECTION COVERS:
Inspect, Replace
INITIAL SETUP
Foot Loop, installed
Maintenance Level
Materials/Parts
Unit
Rope, Manila, Type 1, Cl2, 1/4" Dia.
Tools and Special Tools
Tool Kit,General Mechanics (WP 0029, Table 0027-2, Item 3)
GENERAL
This procedure contains information and instructions to keep the LME fabric assemblies in good working
order by inspecting and replacing damaged foot loops.
INSPECT
Inspect the foot loop for fraying, cuts or loose knots.
If the foot loop is damaged or shows signs of deterioration, replace as follows.
REPLACE
Remove the damaged foot loop.
Cut a 19" length of Manila Rope (1), pass both ends through the grommet (2) and tie off using an
overhand knot (3).
Ensure that the knot is tight. Draw the finished foot loop back through the grommet (2) until the knot is
against the grommet.
END OF WORK PACKAGE