TM 10-5410-223-14/1
Section III. TROUBLESHOOTING
corrective actions. If a malfunction is not listed
3-4. General
(except when malfunction and cause are obvious), or
a. This section contains troubleshooting or
is not corrected by listed corrective actions, you
malfunction information and tests for locating and
should notify organizational maintenance,
correcting most of the troubles which may develop in
3-5. Operator Maintenance Troubleshooting
the shelter. Each malfunction or trouble symptom
for an individual component or unit is followed by a
Table 3-2 list the common malfunction that
you
list of tests or inspections necessary for you to
may find during the operation or maintenance of the
determine probable causes and suggested corrective
shelter or its components. You should perform the
actions for you to remedy the malfunction.
tests/inspections and corrective actions in the order
b. This manual can not list all possible malfunc-
listed.
tions that may occur or all tests or inspections, and
Table 3-2. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER LEAKAGE INTO MULTIPURPOSE SHELTER
Step 1. Check for damaged weather seal assemblies,
Report discrepancy to organizational maintenance.
Step 2. Check for loose or improperly positioned seal assemblies.
Report discrepancy to organizational maintenance.
Section IV. MAINTENANCE PROCEDURES
support maintenance. Deviations may be authorized
3-6. General
by the Commanding Officer to meet his operational
All damage requiring repair or replacement shall
requirements.
be reported to organizational or direct and general
3-2