TM 9-4931-374-13&P
3-28. WIRE ASSEMBLY (CEILING OUTLETS)--MAINTENANCE INSTRUCTIONS
THIS TASK COVERS:
a. Removal
d. Repair
b. Inspection
e. Reassembly
c. Disassembly
f. Installation
INITIAL SETUP
Special Tools
WARNING
Basic aircraft armament repairman tool set (SC
The shop set contains voltages which are
4933-95-CL-A13)
dangerous if contacted. Before perform-
Fire control repair shop set (SC 4931-95-CL-A21)
ing any maintenance on the wiring assem-
Supplemental aircraft armament repairman tool set
bly, be sure the circuit breaker on power
(SC 4933-95-CL-A14)
distribution panel connected to power
source is in OFF position and the 120/-
Material s/Parts
208V cable assembly is disconnected from
Abrasive cloth (item 4, app D)
the shop set.
Lug terminal (MS25036-156)
References
NOTE
Appendix D
There are two wire assemblies (tagged no.
Appendix E
11A and no. 11B) used in the J20 and J21
3-46 Disassembly and reassembly procedures for
conduit boxes to ground the electrical
shop set--electrical installation--main-
tenance instructions.
one 4.00-in. (10.16-cm) green wire with
a lug terminal attached to one end. The
following procedures are written for a
quantity of one wire assembly and must be
repeated for the second wire assembly.
3-234