TM 9-2330-390-14&P
2-11. RAISING DOLLY SET WITH OR WITHOUT SHELTER AND COUPLING TO TOWING
VEHICLE (Cont).
NOTE
If raising dolly set with shelter, perform steps d through g.
d.
Route intradolly air hoses (7) and intradolly cable (3) over top of shelter (13) on its centerline.
e.
Connect one end of each intradolly air hose (7) to service (blue) and emergency (red) gladhands (4 and
8) on front dolly pivoting tray (9). Connect other end of each intradolly air hose to service (blue) and emergency (red)
gladhands on rear dolly pivoting tray (10).
f.
Connect intradolly cable (3) between 24-volt receptacle connector (6) at forward junction box (5) and
24-volt receptacle connector (2) at rear junction box (1).
2-78