TM 10-7310-281-13&P
MODERN BURNER UNIT (MBU)
0005 00
OPERATION UNDER USUAL CONDITIONS
0005 00-10
WARNING!
Two Person Lift
The Battery Pack weighs approximately 80 pounds (36.3 kg). Two persons must carry the
Battery Pack, lifting with legs, not back, to prevent injury.
Connecting Power Cables In The KCLFF -(E) Using Vehicular Power and Battery Pack. If the
battery pack (1) is used to supplement vehicular power, connect the NATO adapter cable (2) to the
Power Input Connector (3) of the Battery Pack (1). Then, with the Battery Pack 3-position function
switch (4) OFF, connect one end of the 25ft (24V DC) extension (5) (if required for additional length) to
the Battery Pack Power Output Connector (6). The 2 Branch cable (7) can then be connected to the
opposite end of the 25ft Extension Cable (5). The cable branches (8) are then connected to the power-
in receptacle of the individual burners (9).
Connecting Power Cables Using Vehicular Power and Battery Pack
1
2
5
3
4
6
7
8
9