TM 10-7310-281-13&PMODERN BURNER UNIT (MBU)0005 00OPERATION UNDER USUAL CONDITIONS0005 00-6Place the retaining bar (4) through the handle of the power converter (6) and over the two mountingbracket shafts (5). Be sure to keep the bar level while sliding over the shafts to prevent binding. Installthe two wing nuts (3).Power Converter Mounting Bracket With Power Converter InstalledConnecting Cables in the MKT. With the power converter in position on the mounting bracket, connectthe end of the Crossway Cable (1) extending up through the floor of the cooling cabinet to the loweroutput connector (2) on the power converter (3).Connect the main connector (4) of the 2 branch cable to the upper output connector (5) of the powerconverter (3).Connect the end of the Feedway Cable (6) extending up through the floor of the cooling cabinet to thepower cord (7) of the power converter (3).Pass the remainder of the 2 branch cable through the left side of the cooling cabinet and distribute itunder the two M59 Field Ranges(8).Pull the individual branch cables (9) out the front of each appliance and connect each branch to thepower-in receptacle (10) of each MBU.Distribute a 4 branch cable (11) along the floor in front of the appliances (12) on the opposite side of theMKT.Connect the main connector (13) of the branch cable to the end of the Crossway Cable (14) extending upthrough the floor of the MKT opposite the cooling cabinet.Hang the 4 branch cable along the front of the appliances with cable clips (15) provided with the MBU.1 (cutaway for clarity)23456