TM 10-5411-224-14
5-12.
HANDHOLD ASSEMBLY.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
General Mechanics Tool Kit (Item 1, Appendix B)
Materials/Parts:
Handhold Assembly
Sealer (Item 19, Appendix E)
Alcohol, Isopropyl (Item 7, Appendix El
Cloth, cotton (Item 3, Appendix El
Gloves, rubber (Item 11, Appendix E)
Lockwashers (Item 20, Appendix E)
REMOVAL
1.
Remove four screws (1), lockwashers (2), and flat washers (3) securing handhold (4) to shelter roof.
2.
Remove handhold from shelter.
INSTALLATION
WARNING
Alcohol solvents are flammable. Keep away from heat, sparks, and open flame. Keep containers closed when
not in use. Use only in well ventilated areas. Avoid prolonged breathing of vapors or repeated contact with
skin.
1.
Clean the roof mounting area for handhold (4) using nonresidual cleaning solvent (Isopropyl alcohol) and
cotton cloth.
WARNING
To avoid injury to personnel, gloves must be worn when working with polysulfide sealer.
5-31