TM 10-5411-201-14
T.O. 35E4-178-1
Section IV.
PREPARATION FOR STORAGE AND SHIPMENT
4-50.
PREPARATION FOR STORAGE AND SHIPMENT.
The following steps describe
procedures for storing or shipping the shelter.
a.
Inspection.
Inspect the shelter for the following:
(1) Make sure all circuit breakers and switches in OFF position.
(2) Hake sure circuit breaker panel door is closed.
(3) Make sure equipment container is strapped down to shelter floor.
(4) Make sure caps are secured on power entry panel receptacles and
binding posts are tightened.
(5) Make sure the stop plate in the load balancer is in the down
position and secured with the pin.
(6) Make sure all lights and jacks are secured in their stowage
positions.
(7) Make sure the foot bolt and chain bolt are secured.
(8) Make sure the receptacle outlets are stowed and the roof struts
are secured.
(9) Make sure all doors are securely closed.
(10) Make sure camlock pin is engaged in hole or corner post.
b. Packing.
Be sure all components are clean and dry before packing.
C A U T I O N
Use care when transporting or storing shelter to
prevent damage to shelter.
c. Care and Storaqe
facility.
If stored outs
inside the shelter.
Store shelter in a dry area or a designated supply
de in humid conditions, check quarterly for dampness
4-194
CHANGE 2