TM 10-5411-201-14
T.O. 35E4-178-1
4-31.
(cont)
3.
Inspect for and replace if necessary:
a.
Missing or damaged components.
Corrosion or paint damage.
R E P A I R
1.
Corrosion or paint damage (Refer to paragraph 4-44)
2.
Replace damaged tie-down ring or strap assembly.
INSTALLATION
1.
2.
3.
4.
5.
6.
Position draw pull catches (11) on equipment container (3) and
secure with rivets (10).
(Refer to paragraph 4-33)
Position safety hasp (9) on equipment container (3) and secure with
rivets (8).
(Refer to paragraph 4-33)
Position hinges (7) on equipment container (3) and secure with
rivets (6).
(Refer to paragraph 4-33)
Position chest handles (5) on equipment container (3) and secure
with rivets (4).
(Refer to paragraph 4-33)
Position equipment container (3) on floor panel.
Install two tie-down rings (1) at the end of two strap assemblies
(2) in holes in floor panel. to secure equipment container (3) to
floor.
NOTE
The procedures in paragraphs 4-31 through
4-43 are typical and apply for all panel
surfaces.
4-32.
DRYING WATER-SOAKED AREAS IN PANELS.
a.
Care shall be taken to prevent water from entering panel core
material, since it is very difficult to remove.
When damage occurs, the
punctured panel skin shall be temporarily protected to prevent entry of water
until repair can be made.
If water has been allowed to enter panel, the care
material shall be dried prior to skin repair.
b.
Position heat lamps around damaged area.
Adjust lamps so that panel
surface temperature does not exceed 200°F (93.3°C).
c.
Allow heat lamps to remain in position until core material
surrounding damaged area is thoroughly dry.
4-153