TM 10-5411-201-14
T.O. 35E4-178-1
4-27.
(cont)
INSTALLATION
1.
Apply sealing compound to interface areas of sidewall panel (6) and
mating surfaces.
2.
From outside shelter, position sidewall panel (6) on fixed floor and
push inward until sidewall is against mating surfaces.
3.
Align sidewall panel mounting holes with inserts in fixed roof and
floor.
NOTE
Align mounting holes at sidewall panel corners
and install bolts.
Check that remaining holes
and inserts are aligned and free from obstructions.
4.
Install washers (9), lockwashers (8), and bolts (7) securing
sidewall panel (6) to fixed roof.
5.
Install washers (5), lockwashers (4) and bolts (3) securing sidewall
panel (6) to fixed floor.
6.
Align corner enclosures (2)
with anchors in sidewall panel
(6) and install screws (l).
7.
Install ECU or closeout panels.
4-137