TM 10-5411-201-14
T.O. 35E4-178-1
4-28.
1.
2.
3.
4.
5.
6.
7.
8.
9.
(cont)
Lower hinged sidewall to hinged
floor in accordance with paragraph
2-16.
Lift stop plates (1) from support
cables (2) on both load balancers
(3) mounted on fixed roof.
Lift hinged floor until almost closed
then lower stop plate (1) to remove
weight from support cables (2) and
secure hinged floor in this position.
Remove screw (4) from cable guide
bracket (5) and disengage support
cable (2).
W A R N I N G
Do not attempt to disassemble or repair load balancer.
This item is a spring powered mechanism and injury or
death to personnel may result if opened. Never completely
release all the tension from the reel assembly or the
cable wrapped around the drum will become tangled.
Return floor to stowed position.
Remove screws (6) securing roller
assembly (7) to corner post (8).
Remove screws (9), lockwashers
(10), and washers (11) securing
roller assembly (12), plate (13),
and seal (14) to endwall hinge
(15) .
Support load balancer (3) and remove
screws (16), lockwashers (17), and
washers (18).
Lower load balancer from fixed roof.
10.
Pull support cable (2) through corner
post (8) and remove roller assemblies
(7 and 12), plate (13), and seals (14)
from support cable.
4-139