TM 10-5411-201-14T.O. 35E4-178-14-21.(cont)3.Disengage all latches (1) along hinged sidewall, hinged endwalls,and hinged roof.CAUTIONSupport inner tube while disengaging support strutfrom stowage bracket.4.Pull lock pins (2) to free support struts (3) from stowage brackets(4) and swing downward.5.Insert lock pins (2) to secure struts in extended position.6.Raise hinged roof to full height of struts.7.Rotate jack handles to lower both expanded side jacks until hingedfloor is clear of hinged endwalls.8.Remove screws (5) and lockwashers (6) and remove pin retainer (7)from hinged endwall (10).9.Support hinged endwall, straighten Lower hinge pins, and remove pins(8) and (9).10.Remove hinged endwall.4-90