TM 10-5411-201-14
T.O. 35E4-178-1
4-21.
HINGED ENDWALL REPLACEMENT AND REPAIR
This task covers:
a.
Removal
d.
Repair
b.
Disassembly
e. Assembly
c.
Cleaning, Inspection
f.
Installation
INITIAL SETUP
Special Tools
Equipment Condition
Hand blind riveter, Appendix B,
Closeout panel removed from
Item 2
hinged endwall
Standard tools
Materials
General mechanics tool kit
Adhesive, Item 2, Appendix E
Personnel - 4
Sealing Compound, Item 19,
1 Electrician
Appendix E
NOTE
The following procedures apply to left and right
hinged endwalls.
REMOVAL
Hinged Endwall
WARNING
The shelter contains voltages that are dangerous if
contacted.
Before removing or installing electrical
cables or components, make certain electrical power
is completely disconnected from circuit involved.
1.
Set circuit breakers CB3 and CB7 or CB5 to OFF position.
2.
Move receptacles from hinged endwall and stow out of way.
4-89