TM 10-5411-200-14T.O. 35E4-177-12-12.(cont)WARNINGExpandable section (hinged floor and hinged sidewalltogether) weighs 700 pounds (318 kg). Do not standdirectly in front of hinged section.i.Raise cam lock handles on corner posts and rotate as indicated todisengage hinged floor locks.Carefully lower hinged floor to the extent of support cable travel(1-1/2 in. (3.8 cm) below level).W A R N I N GThe stop plate cable assembly is a spring poweredmechanism.Personal injury or death may result iftwo quick release pins are not installed in thestop plates.k.Install. two quick release pins in stop plates on load balancers(inside shelter) to prevent return of support cable.l.Remove two support braces from equipment container.m.Raise hinged sidewall and hold in position.n.Install the two support braces in brace cups on hinged floor andsidewall behind support cable.o.Remove two leveling jacks from inside of left cargo door.p.Position jacks at each corner of expanded side.2-22 CHANGE 2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business