TM 10-5411-200-14
T.O. 35E4-177-1
2-9.
(cont)
LOCATION
ITEM
ACTION
5.
Fixed floor base a.
Lower mobilizer
Check for security and
frame
fittings
condition.
b.
Lower ISO fittings
Inspect fittings for damage.
c.
Frame edge and
Inspect for damage.
fork lift opening
6.
Corner posts
Components
Inspect for missing, bent,
or damaged components.
2-10.
SHELTER HANDLING
Do not use handling equipment with capacity of less
than gross weight of system.
Do not allow shelter
to swing back and forth when suspended.
Failure to
observe this WARNING may result in damage to equipment
or severe injury or death to personnel.
NOTE
Dollyset M832 mobilizer used only if gross weight of
shelter system is 10,000 pounds (4546 Kg) or less.
Dollyset XM1022 or hoisting sling (with cable breaking
strength of 35,000 pounds) used if gross weight of shelter
system is over 10,000 pounds (4546 kg).
When using fork lift, make sure it has a minimum tine
length of six feet.
Use inner slots for fork lifting
an empty shelter only.
Use 20-foot container lift sling (bottom lift, type II,
with a 20 long ton safe working load) with aluminum
spreader, Appendix D.
2-13