TM 10-5411-200-14T.O. 35E4-177-14-27.(cont)2.Lift stop plates (1) from support cables (2) on both load balancers(3) mounted on fixed roof.3.Lift hinged floor until almost closed then lower stop plate (1) toremove weight from support cables (2) and secure hinged floor inthis position.4.Remove screw (4) from cable guide bracket (5) and disengage supportcable (2).W A R N I NGDo not attempt to disassemble or repair load balancer.This item is a spring powered mechanism and injury ordeath to personnel may result if opened. Never completelyrelease all the tension from the reel assembly or thecable wrapped around the drum will become tangled.5.Return floor to stowed position.6.Remove screws (6) securing roller assembly (7) to corner post (8).7.Remove screws (9), lockwashers (10), and washers (11) securingroller assembly (12), plate (13), and seal (14) to endwall hinge(15) .8.Support load balancer (3) and remove screws (16), lockwashers (17),and washers (18).4-134