TM 10-5411-200-14
T.O. 35E4-177-1
4-26.
(cont)
4.
Remove bolts (6), lockwashers (7), drip cap (8), and washers (9).
5.
Strip seal (10) away from opening.
CLEANING, INSPECTION
1.
Clean panel and component surfaces.
2.
Inspect mounting surfaces for corrosion and damage.
3.
Inspect for and replace if necessary:
a.
Missing or damaged components
b,
Corrosion or paint damage.
R E P A I R
1.
Panel skin damage.
(Refer to paragraphs 4-31 through 4-42.)
2.
Corrosion or paint damage.
(Refer to paragraph 4-43)
ASSEMBLY
1.
When assembling endwall panel to roof, position drip cap (8) and
install washers (9), lockwashers (7) and bolts (6).
2.
position upper mobilizer fitting (3) and install lockwashers (2) and
screws (l).
3.
Position level (5) and install rivets (4).
(Refer to paragraph 4-32)
4-130