TM 10-5411-200-14T.O. 35E4-177-14-16. (cont)9. Connect wires from left side roof beam (23) to each of three fixed roofarea ceiling lights (26). (Refer to paragrapg 4-46.)10. Attach three fixed roof area ceiling light covers (25) to three fixedarea ceiling lights (26) with nine screws (24).11. Connect wires from left side roof beam (23) to junction box (3).(Refer to paragraph 4-46)12. Attach junction box cover (2) to junction box (3) by installing fourscrews (1).13. Connect wires from left side roof beam (23) to circuit breaker box(19). (Refer to paragraph 4-46)14. On both models,circuit breaker(21).15. On model NQOB,position panelboard (22) over circuit breakers inbox (19) and secure with four screws (20) and washersinstall panel cover (18) on the circuit breakerpanelboard (22), move four clamp fingers (17) to the CLOSE position andtighten captive screws (16).16. Close circuit breaker panel door (15).RightSideRoof BeamWiring1.Position right side roof beam (4) against roof and install washers(14), lockwashers (13), and bolts (12).2. Connect conduit locknuts (11) between junction box (3) and right sideroof beam (4).3.Install three push bar assembly pins (10).4.Connect wires from right side roof beam (4) to rear of two receptacles(8). (Refer to paragraph 4-46)5.Install two receptacles (8) in two outlet boxes (9) and secure withfour screws (7).6. Attach receptacle cover (6) to outlet box (9) with screw (5) at eachend of right side roof beam (4).7. Connect wires from right side roof beam (4) to junction box (3).(Refer to paragraph 4-46)8. Attach junction box cover (2) to junction box (3) by installing fourscrews (l).CHANGE 24-55