TM 10-5410-284-13&PTM 10602A-13&PLIGHTWEIGHT MAINTENANCE ENCLOSURE (LME)0010 00PREVENTIVE MAINTENANCE CHECK AND SERVICES (PMCS) 0010 00-6THIS SECTION COVERS:PMCS Checks and ServicesINITIAL SETUP:Lights, unpacked or installedMaintenance LevelUnitTable 0010 00-1. Preventive Maintenance Checks and Services for LME - continued.ITEMINTERVALMAN-ITEM TO BEPROCEDUREEQUIPMENTNO.HOURCHECKED ORNOT READY/SERVICEDAVAILABLE IF:4Before,LightsWARNINGDuringLethal voltage is present if the lights are connected tothe power distribution box. If the lights are in use duringPMCS, limit procedure to a visual inspection. Seriousinjury or death by electrocution may occur if a live wireis touched. Inspect for missing or damaged components such aslights damaged,plastic covers (1) on individual lights, and end capsweb strap hangers(2)., Inspect for missing or frayed light support strapsmissing or frayed,(3) or missing hardware (4). Ensure that light bulbs (5)with hardwareare installed. missing. No lightbulbs available.Lights inoperative.