TM 10-5410-284-13&P
TM 10602A-13&P
LIGHTWEIGHT MAINTENANCE ENCLOSURE (LME)
0010 00
PREVENTIVE MAINTENANCE CHECK AND SERVICES (PMCS)
0010 00-6
THIS SECTION COVERS:
PMCS Checks and Services
INITIAL SETUP:
Lights, unpacked or installed
Maintenance Level
Unit
Table 0010 00-1. Preventive Maintenance Checks and Services for LME - continued.
ITEM
INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
4
Before,
Lights
WARNING
During
Lethal voltage is present if the lights are connected to
the power distribution box. If the lights are in use during
PMCS, limit procedure to a visual inspection. Serious
injury or death by electrocution may occur if a live wire
is touched.
Inspect for missing or damaged components such as
lights damaged,
plastic covers (1) on individual lights, and end caps
web strap hangers
(2)., Inspect for missing or frayed light support straps
missing or frayed,
(3) or missing hardware (4). Ensure that light bulbs (5)
with hardware
are installed.
missing. No light
bulbs available.
Lights inoperative.