TM 10-5410-229-13&P
1-10.
LOCATION AND DESCRIPTION OF MAJOR PARTS - Contd.
Two, 3/4 " wide roll up straps are located just above the window flap. A 1" wide hook fastener strip is located around the
outside seam of the window opening. Two window walls are issued with each MCPS.
(4)
Entrance Way Wall. The entrance way wall (4) is constructed similar to the plain wall except that there are no
quick release female fasteners located along the inside top. Additionally, this wall incorporates a 36" wide covered
entrance way. Inner blackout doors cover the entrance way opening in the wall. A 1" wide pile fastener strip is sewn along
its top edge. A 1" wide hook fastener strip is located along the top of the entrance way wall opening. Left and right
blackout door assemblies are sewn to the outer seams of the entrance way wall opening. Both have two poleholders
located on the outside approximately 35" apart, and three buckle assemblies with quick disconnect female fasteners on
the inside. A grommet is located on each upper and lower corner of the left and right blackout door assemblies. A male
quick disconnect fastener is located on the front center of the entrance way roof. An identification label is sewn on the
inside of the wall. The covered entrance way allows for entry into and exit from the tent, enhances ventilation and helps
maintain light discipline. One entrance way wall is issued with each MCPS.
(5)
Entrance Way/Window Wall Liner. The entrance way/ window wall liner (5) is constructed similar to the plain
wall liner except that it contains an approximately 61/2" high and 3 wide door. A quick release male fastener is located on
the upper, inside edge of the door and a quick disconnect female fastener in corresponding location on the liner. A strip of
1" pile fastener is located along the left side and along the top of the liner door opening. A strip of 1" hook fastener is sewn
to the outer edge and top of the door. In addition seven quick release female fasteners are located on the outside along
the door opening. Three entrance way wall/window wall liners are issued with each MCPS.
(6)
Roof Cap. The roof cap (6) is constructed of the same material as the walls. On the inside, 8" wide
reinforcements are located along the front and rear, with quick disconnect female fasteners located approximately 18"
apart. Two strips of 2" wide hook fastener are sewn to the reinforcement. Along the sides, 16 1/2" reinforcements are
located, with quick disconnect female fasteners spaced approximately 18" apart. Two strips of 2" wide hook fastener are
sewn to the reinforcement below the fasteners. In addition, strap assemblies with quick disconnect fasteners are located
on the upper part of the reinforcement. An 11" x 24"
1-6