REPAIR FIELD TABLE - Contd - TM-10-5410-229-13P_115
REPAIR LIGHT SET - Contd - TM-10-5410-229-13P_117
TM-10-5410-229-13P Modular Command Post System (MCPS) Green NSN 5410-01-323-2454 Tan NSN 5410-01-334-7529 Manual
Page Navigation
99
100
101
102
103
104
105
106
107
108
109
TM 10-5410-229-13&P
5-10.
REPAIR FIELD TABLE
- Cont’d
(2) Install Brace.
(a)
Align new brace (2) with rivet holes in top weldment (3), and leg weldment (4).
(b)
Install rivets (1). (See paragraph 5-6.b. for rivet replacement procedures.)
5-11.
TEST AND REPAIR LIGHT SET, Type II
This task covers:
a.
Test Ballast Assembly
b.
Remove and Install
Ballast
Assembly
c.
Remove and Install Female Cable Assembly
d.
Remove and Install Male Cable Assembly
e.
Remove and Install Switch
f.
Remove and Install
Fuseholder
g.
Remove and
Install Handles
, Hinges, and
Latches
INITIAL SETUP
Tools:
Tool Kit, Common Number 1 (Appendix B, Section III, Item 7)
Multimeter
(Appendix B, Section III, Item 4)
Materials/Parts:
Ballast
Assembly (Appendix C, Figure 5, Item 27)
Cable Assembly, Female (Appendix C, Figure 5, Item 10)
Cable Assembly, Male (Appendix C, Figure 5, Item 18)
Fuseholder
(Appendix C, Figure 5, Item 21)
Handle (Appendix C, Figure 6, Item 2)
Hinge (Appendix C, Figure 6, Item 3)
Latch (Appendix C, Figure 6, Item 1)
Switch (Appendix C, Figure 5, Item 23)