TM 10-5411-200-14
T.O. 35E4-177-1
4-10. (cont)
7.
Loosen four captive screws (11) and remove limit switch cover (12).
8.
Disconnect three sets of wires plus one ground wire inside limit switch (13).
NOTE
Tag wires for reconnection.
9.
Pull wires up through lower conduit (14) and into light fixture adapter (9).
10.
Remove two screws (30) and lo&washers (31) and separate outlet box (27) from wall.
11.
Loosen two insulating connectors (15) below light fixture adapter (9) and:
a. For units prior to S/N 1089, loosen insulating conduit connector (15) at elbow (28) and remove
conduit (14).
b. For units with S/N 1089 and subsequent, loosen insulating conduit connector (15) at switch box (27)
and remove conduit (14).
12.
Loosen screw (17) at rear of offset connector (18).
13.
Remove two screws (19) and lockwashers (20) from light fixture adapter (9).
4 - 2 4