TM 9-4931-374-13&P
3-21. SWITCHBOX AND MOUNTING BRACKET (WITHOUT TOGGLE SWITCH)--MAINTENANCE INSTRUCTIONS (cont)
ADJUSTMENT OF MICROSWITCH
TEST
NOTE
Adjusting two hex nuts
inward
moves
plunger
1
PERSONNEL DOOR
AND
CARGO
forward, adjusting outward
DOOR. Close.
moves plunger backwards.
PLUNGER
(1)
OF
MICROSWITCH (2).
Adjust two hex nuts (3).
NOTE
Blackout switch (1) is located
on switchbox (2) above
personnel door.
The three switches (S1, S2,
and S3) (3) are located on the
circuit breaker panel box (4)
to the right of the personnel
door.
2
BLACKOUT SWITCH
(1).
Turn
to
NORMAL position.
3-202