TM 9-4931-374-13&P
16
TWO CONNECTORS (21) ON FLEXIBLE CONDUIT (22) BETWEEN
SWITCHBOX S7/S8 (23) AND CIRCUIT BREAKER PANEL BOX PL1
(18). Loosen.
17
FLEXIBLE CONDUIT (22) AND TWO CONNECTORS (21). Remove.
REPAIR
1
CONDUIT (1) WITH FITTING (2).
NOTE
Newly installed connectors
a. Remove fitting (2).
and fittings may be loose and
should be secured in place
b. Replace conduit (1), if needed, by
with tape (item 19, app D)
fabrication (fig. 5 and 6, app E)
until installed in conduit
boxes.
c. Replace and
install
fitting
(2)
as
required.
Repair is by replacement of
authorized parts (app C).
3-119