TM 9-4931-374-13&P
9
FOUR 0.31-IN. (0.79-CM) HOLES (18).
Drill in lower shelving (21) as illustrated.
10 FOUR 0.31-IN. (0.79-CM) HOLES (18). Drill
through table top (22) as illustrated.
REASSEMBLY
NOTE
Before
reassembling
the
1
HARNESS ASSEMBLY (1).
electrical installation, check
the wiring diagram (fig. 3-1),
a. Pull through flexible conduit (2) from
the schematic diagram (fig. 3-
switchbox S7/S8 (3) to circuit breaker
2), and the wire table (p 3-74).
panel box PL1 (4).
Using harness assembly with
b. Remove all tape (5).
ends of six wires taped
together, perform step 1,
ensuring the ends with lug
terminals are left in switchbox
S7/S8.
3-79