TM 9-2330-390-14&P4-125. FUEL TANK MAINTENANCE (Con’t).CLEANING AND INSPECTION Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protectivegoggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame orexcessive heat. The solvent’s flash point is 100° F-138º F (38° C-59° C). If youbecome dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If solvent contacts eyes, immediately wash your eyes and seek medicalattention.Compressed air used for cleaning or drying purposes, or for clearing restrictions,should never exceed 30 psi (207 kPa). Wear protective clothing (goggles/shield,gloves, etc.) and use caution to avoid injury to personnel.1.Clean all removed metal components in dry cleaning solvent and dry with compressed air.2.3.4.Handle fuel filter with care. Rough handling will cause damage.Clean fuel filter with compressed air.Inspect all removed components for cracks, breaks, holes, tears, or damaged threads. Replace damagedcomponents.Inspect fuel tank for missing or illegible labels. Replace damaged labels (see paragraph 4-106).1.Install fuel indicator (3) on fuel tank (2) with twoclips (26).2.Install strainer (25) and cap (1) on fuel tank (2).4-370