TM 9-2330-390-14&P4-142 Change 44-62.FRONT DOLLY RELAY EMERGENCY VALVE AND AIR RESERVOIR REPLACE-MENT (Con't).NOTEMale threads of fittings should be coated with antiseize tape if not already fac-tory-coated with an antiseize compound.1.Install elbow (3) and draincock (15) on air res-ervoir (4).2.Install elbows (6 and 16), nipple (18), tee (9),and two plugs (17) on relay emergency valve(1).3.Apply sealing compound to threads of hex pipenipple (19). Install hex pipe nipple on relayemergency valve (1).4.Install reducer (22) on tee (20).5.Install nipple (21) and tee (20) on air reservoir(4).6.Install hex pipe nipple (19) and relay emer-gency valve (1) on tee (20).7.Install air reservoir (4) with relay emergencyvalve (1) on pivoting tray (12) with three cap-screws (11), eight flatwashers (13 and 23), andfour new locknuts (14).b.INSTALLATION23
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business