TM 9-2330-390-14&P
4-142 Change 4
4-62.
FRONT DOLLY RELAY EMERGENCY VALVE AND AIR RESERVOIR REPLACE-
MENT (Con't).
NOTE
Male threads of fittings should be coated with antiseize tape if not already fac-
tory-coated with an antiseize compound.
1.
Install elbow (3) and draincock (15) on air res-
ervoir (4).
2.
Install elbows (6 and 16), nipple (18), tee (9),
and two plugs (17) on relay emergency valve
(1).
3.
Apply sealing compound to threads of hex pipe
nipple (19). Install hex pipe nipple on relay
emergency valve (1).
4.
Install reducer (22) on tee (20).
5.
Install nipple (21) and tee (20) on air reservoir
(4).
6.
Install hex pipe nipple (19) and relay emer-
gency valve (1) on tee (20).
7.
Install air reservoir (4) with relay emergency
valve (1) on pivoting tray (12) with three cap-
screws (11), eight flatwashers (13 and 23), and
four new locknuts (14).
b.
INSTALLATION
23