TM 9-2330-390-14&P4-26. ELECTRICAL REPAIR (Con't).e. FemaleConnectorRepair.(1)Slide back shell (10) and sleeve (11), and cut terminal (12) from wire lead (9). Discard terminal.(2)Remove sleeve (11) and shell (10) from wire lead (9).(3)Remove insulation from wire lead (9)equal to depth of new terminal (12).(4) Slide shell (10) and sleeve (11) onwire lead (9).(5) Position new terminal (12) on wirelead (9) and crimp (Item 29, Appendix G).(6)Slide sleeve (11) and shell (10) overterminal (12).f.ReceptacleConnectorRepair.NOTEMale and female receptacle connectors are repaired the same way. Male connectoris illustrated.(1)Use soldering gun (Item 25, Appen-dix G) to heat soldered connections (15). Disconnectwires (16) from pin locations (14) of receptacle connec-tor (13).(2)Position new wires (16) at appropri-ate pin locations (14). Solder connections using solder(Item 26, Appendix F) and soldering gun (Item 25, Ap-pendix G).4-15