4-26. ELECTRICAL REPAIR (Con't).
e. Female Connector Repair.
(1)
Slide back shell (10) and sleeve (11), and cut terminal (12) from wire lead (9). Discard terminal.
(2)
Remove sleeve (11) and shell (10) from wire lead (9).
(3)
Remove insulation from wire lead (9)
equal to depth of new terminal (12).
(4) Slide shell (10) and sleeve (11) on
wire lead (9).
(5) Position new terminal (12) on wire
lead (9) and crimp (Item 29, Appendix G).
(6)
Slide sleeve (11) and shell (10) over
terminal (12).
f.
Receptacle Connector Repair.
NOTE
Male and female receptacle connectors are repaired the same way. Male connector
is illustrated.
(1)
Use soldering gun (Item 25, Appen-
dix G) to heat soldered connections (15). Disconnect
wires (16) from pin locations (14) of receptacle connec-
tor (13).
(2)
Position new wires (16) at appropri-
ate pin locations (14). Solder connections using solder
(Item 26, Appendix F) and soldering gun (Item 25, Ap-
pendix G).
4-15