TM 9-2330-390-14&P
3-7. CHECKING AND FILLING HYDRAULIC FLUID (Con't).
DO NOT allow dirt or dust to enter hydraulic reservoir. Damage to hydraulic system will
result.
b.
Remove cap (7) from hydraulic reservoir (8). Wipe dipstick (8) clean with a clean rag (Item 25,
Appendix F). Install cap in reservoir.
Hydraulic fluid level differs for M1022A1 and M1022A1 with side lift kit Installed. Proper
level for M1022A1 (STD) Is marked near tip of dipstick. Proper level for M1022A1 with
side lift kit (S/L) Is marked near cap end of dipstick.
c.
Remove cap (7) from hydraulic reservoir (8) and check level of hydraulic fluid on dipstick (6). Level
should be even with FULL (F) mark. If level Is at or below ADD (A) mark, add hydraulic fluid (Item 15, Appendix F).
Install cap in reservoir.
NOTE
3-22