TM 9-2330-390-14&P
3-6. DRAINING AIR RESERVOIR (Con't).
Wear protective eye goggles when opening air reservoir draincock and avoid air
stream. Failure to follow this warning may result In eye Injury.
c.
Open draincock (3) on air reservoir (2). Allow all compressed air and condensation to drain. Leave
draincock open.
d.
Before operation, close draincock (3) on air reservoir (2).
e.
Connect intervehicular and intradolly air lines (see paragraph 2-11).
3-7. CHECKING AND FILLING HYDRAULIC FLUID.
NOTE
Perform this task at both front and rear dolly hydraulic reservolrs.
Dolly set should be lowered to ground with Iift and positioning cylinders fully
retracted to ensure an accurate reading.
a.
Park dolly set on level ground. If pivoting
tray (1) is not level, remove safety pin (4) and hitch pin (5)
and unlock pivoting tray lockout brace (2) from lower
bracket (3).
3-21