TM 9-2330-390-14&P
2-25. OPERATING ENGINE IN EXTREME COLD [BELOW 0°F (-18°C)] (Cont).
(3)
Raise decompression lever (1) and begin cranking by turning starter switch (2) to ST position. After
five seconds of cranking, lower decompression lever (1).
(4)
Continue cranking until black smoke (indicating combustion) is seen in exhaust or until engine runs
without aid of starter. If engine starts but white smoke (indicating fuel) is seen, continue to crank. Engine should start
within 20 seconds.
(5)
After engine starts, turn starter switch (2) to GL position and leave for 30 seconds.
(6)
Turn starter switch (2) to ON position. Set speed control lever (5) to LOW position, Idle engine for a
minimum of five minutes or until engine runs smoothly.
(7)
Set speed control lever (5) to HIGH START position when operating hydraulic control valve.
b. Shutting Down Engine.
(1)
Before shutdown, set speed control lever (5) to LOW position and idel engine for three minutes.
(2)
Push stop lever (4) to the right to STOP position.
(3)
As soon as engine stops, turn starter switch (2) to OFF position. Remove key (3).
c.
Jump Starting Using Cold Start Kit (-26°F to -50°F (-32% to -46%)).
(1)
Attach jumper cable (3) to 12-volt battery in towing vehicle:
(a)
Attach positive (red) alligator clip (2) to positive (+) battery terminal
(b)
Attach negative (black) alligator clip (1) to negative (-) battery terminal.
Change 1 2-144.1