TM 10-8340-226-13&PSECTION VI. UNIT MAINTENANCE PROCEDURESWARNINGSeam sealer and solvent are extremely flammable and fumes toxic - containstoluene and isopropyl alcohol. Do Not smoke or use seam sealer or solvent nearopen flame. Death or serious injury may result from explosion or fire.Use seam sealer and solvent in an open, well-ventilated area away from sourcesof combustion; indoors wear a respirator. Avoid contact with skin and eyes. Weargoggles and gloves when using seam sealer and solvent. Inhalation of fumes maycause toxic sickness.4-9. GENERAL.This section contains unit maintenance procedures applicable to the FSCT components asauthorized by the Maintenance Allocation Chart (MAC), Appendix B of this manual. Repairs will be limited tosewing fabric rips and tears (maximum of six inches in length) or holes (maximum of two inches in diameter)and application of seam sealer. Consult FM 10-16 for specific tentage repair guidelines.4-10. REPAIR FRAME ASSEMBLYThis task covers: RepairINITIAL SETUPTools:Brush (Appendix B, Section III, Item 2)Tentage Repair Kit (Appendix B, Section III, Item 1)Materials/Parts:Bottom Pole Sleeve (Appendix C, Fig. 2, Item 6)Frame Pole, Long (Appendix C, Fig. 2, Item 20)Frame Pole, Short (Appendix C, Fig. 2, Item 18)Hub Assembly (Appendix C, Fig. 2, Item 5)Pole & Hook Assembly (Appendix C, Fig. 2, Item 19)Safety Spring Snap (Appendix C, Fig. 2, Item 3)EquipmentCondition:Frame should be removed from tent to accomplish repairs.4-3