TM 10-7360-211-13&P
Change 7 3-3
Table 3-1. Operator Troubleshooting
1. SINK ASSEMBLY IS NOT STABLE.
Step 1. Check burner rack and base rack for stability.
If not stable, move equipment to level ground.
If not stable, ensure the tabs on the burner rack are inserted in the flue of the sink.
2. SINK ASSEMBLY DOES NOT HEAT WATER PROPERLY.
Step 1. Check to see if the burner flame is on.
Light the burner in accordance with TM 10-7360-204-13&P.
Step 2. Check to see if burner flame is green.
Adjust the burner in accordance with TM 10-7360-204-13&P.
Step 3. Check to see if the burner flame is the proper height for the desired water temperature.
Adjust the burner for the temperature desired in accordance with TM 10-7360-204-13&P.
3. WATER IN SINK DOES NOT DRAIN.
Step 1. Observe water drainage and check for clogged drain.
Remove obstruction from sink drain or drain hose. Thaw if frozen.
Step 2. Check for excessive mud at drain hose output.
Relocate drain hose output end.
4. DRAIN TABLE IS UNSTEADY.
Step 1. Check for proper locking of legs.
Lock legs properly (para 2-6f).
Step 2. Check for bent or broken parts.
Notify unit maintenance.
5. WORK TABLE IS UNSTEADY.
Step 1. Check table for proper locking of legs.
Lock legs properly (para 2-6f).
Step 2. Check for bent or broken parts.
Notify unit maintenance.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION