TM 10-5411-205-13Table 3-1. Troubleshooting.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1.2.3.4.5.OUTER DOOR OR INNER DOOR DOES NOT OPEN OR CLOSE SMOOTHLYStep 1.Inspect hinges for adequate lubrication.Lubricate as required (paragraph 3-1).Step 2.Adjust or repair door as necessary (paragraph 3-19).OUTER DOOR OR INNER DOOR DOES NOT STAY OPENStep 1.Check to see if detent pin is installed in door stay channel.Install detent pin in channel.Step 2.Check to see if detent pin is missing.Install detent pin on door (paragraph 3-32.f).DOOR HANDLE IS JAMMED OR DOES NOT OPERATE SMOOTHLYStep 1.Inspect components for adequate lubrication.Lubricate as required (paragraph 3-1).step 2.Inspect door handle and latching mechanism for missing or damage com-p o n e n t s . Repair or replace components as required (paragraph 3-19).LOUVER COVER DOES NOT STAY OPENStep 1.Check to see if holder assembly is attached to louver cover.Attach holder assembly to louver cover.Step 2.Check to see if holder assembly is secure or damaged.Repair or replace components as required (paragraph 3-24).WATER IS GETTING INTO SHELTERStep 1.Check condition of weather gaskets around the inside edge of each door,Replace deteriorated gaskets (paragraph 3-18).3-9