TM 10-5411-201-14
T.O. 35E4-178-1
2 - 1 0.
(cont)
( 2 ) T h e I S O l i f t i n g d e v i c e s h o u l d c o n t a ct
f o u r l o w e r I S O f i t t i n gs
only and not make any other contact with shelter.
( 3 ) T e r m i n a l f i t t i n g s s h a l l b e i n s t a l l e d s o t h a t l i f t i n g f o r c e s a r e
exerted not more than 1-1/2 in. (38 mm) away from ISO fittings.
( 4 ) H o i s t s h e l t e r a n d p o s i t i o n t o d e s i r e d l o c a t i o n .
c.
F o r k l i f t i n g f r o m f o r k l i f t s l o t s i n b a s e f r a m e.
( 1 ) F o r k l i f t a r m s s h a l l b e a t l e a s t 6 f t ( 1 . 8 m ) l o n g.
( 2 ) U s e c a r e w h e n i n s e r t i n g f o r k l i f t a r m s i n f o r k l i f t s l o t s.
( 3 ) U s e i n n e r s l o t s f o r f o r k l i f t i n g a n e m p t y s h e l t e r o n l y.
( 4 ) U s e o u t e r s l o t s f o r f o r k l i f t i n g s h e l t e r w i t h m a x i m u m p a y l o a d.
d.
D o l l y s e t l i f t i n g f r o m m o b i l i z e r f i t t i n g s .
(1) Separate Dollyset sections and prepare for use observing all
recommendations of Dollyset technical manual.
( 2 ) P o s i t i o n D o l l y s e t s e c t i o n s a t e n d s o f s h e l t e r a d j a c e n t t o
m o b i l i z e r f i t t i n g s a t s h e l t e r e n d w a l l s.
2-15